INTERZINC 315 PDF

  • No Comments

Interzinc B. Storage Conditions: All painting materials shall be stored in a clean, dry, well ventilated place, protected from sparks, flame. A three component, metallic, zinc rich epoxy primer which passes Slip B coefficient. Interzinc B complies with SSPC Paint 20 and contains minimum 80%. Interzinc Call for Price. A two component high solids, low VOC metallic zinc- rich epoxy primer formulated on proprietary polymer technology which provides.

Author: Mizragore Gukazahn
Country: Bahamas
Language: English (Spanish)
Genre: Software
Published (Last): 20 August 2018
Pages: 76
PDF File Size: 5.91 Mb
ePub File Size: 6.18 Mb
ISBN: 632-6-78640-986-9
Downloads: 85438
Price: Free* [*Free Regsitration Required]
Uploader: Mazushura

Structural steel and framing with reference to primer receiving fire protection materials. International Interzibc, LLC, which is located at: Coating will be a complete system from a single source consisting of primer and topcoat. Temporary protection and heat shall be maintained at this minimum temperature for 24 hours before, during and 24 hours after material application.

All batch number, product identification and quantities shall be recorded on appropriate QC documents. Areas will be designated by the Architect.

Interzinc – A k i r a

Deliver materials in manufacturer’s original, sealed, undamaged container with identification label intact. Provide masking, drop cloths or other suitable coverings to prevent overspray onto surfaces not intended to be affected by Work in this section. Submit plan, section, elevation and perspective drawings as necessary to depict system configuration, design considerations and application procedures.

Wood, interiznc, concrete, concrete masonry walls, ceilings, soffits, walkways, curbs, steps. Items specified or provided with factory finish; materials and products having factory-applied primer are not considered factory finished. Moderate Atmosphere Applications – Industrial and coastal areas. Moderate sulpher diuoxide levels.

Protect adjacent areas from over spray of coating material. If this location falls within a mile radius of the project site, then Interchar can contribute to earning Materials and Resources Credit 5. Interior chemical processing areas and swimming pools.

All products listed in this interainc must be manufactured under the appropriate follow-up service with each container bearing the certified label mark.

Substrate and air temperature shall be in accordance with the manufacturers requirements. International Protective Coatings is the leading supplier of high performance Protective Coatings and forms part of Akzo Nobel, a market driven, technology based company specializing in Coatings, Chemicals and Pharmaceuticals.

  HANS VAIHINGER DIE PHILOSOPHIE DES ALS OB PDF

Equipment and application procedures must conform to the coating manufacturer’s application instructions. Store and dispose of hazardous materials, and materials contaminated by hazardous materials, in accordance with requirements of local authorities having jurisdiction. Do not apply coatings under environmental conditions outside manufacturer’s absolute limits. Clean integzinc free of dust, dirt, grease or other foreign substances that would impair the bond of the coating.

Provide ventilation in areas to receive work of this section during application and minimum 24 hours after application. Grind smooth all weld spatter and defects prior to commencement of coating application. Pipes, ducts, conduits, hangers and supports, equipment, and equipment enclosures exposed to view in all rooms and spaces except mechanical rooms, electrical rooms, and utility rooms.

Apply material at the required dry film thickness. All surfaces to interzlnc coatings must be clean, dry and free of oil, grease, loose mill scale, dirt, dust or other foreign substances which would impair bond of the material to the substrate.

Coordinate with Section and Contract Drawings for all Moderate Atmosphere areas of the project.

Interzinc 315B

International Imterzinc has operations in 54 countries worldwide and over 3, employees. High Performance coatings applied in the field with Company specializing in manufacturing products listed in this section with a minimum of ten 10 years documented experience.

Submit product data including manufacturer’s technical information indicating product performance characteristics, performance and limitation criteria. Do not commence adjacent or adjoining Work until the application of the coatings intdrzinc complete in that area. Submit applicators current certification as a manufacturer trained and approved applicator. Provide a mock-up for evaluation of surface preparation techniques and intezinc workmanship.

When deciding on the extent of the mock-up, consider all the major different types of work on the project. Verify that substrate and workspace temperature and humidity conditions are in accordance with requirements of this section.

For each finish product specified, two complete sets of color chips representing manufacturer’s full range of available materials. Apply finish coat in accordance with the manufacturer’s application instructions. Company specializing in applying the work of this section with a minimum of three 3 years documented experience and certified by the manufacturer. Surfaces Not to be Painted: The following is one example of how a mock-up niterzinc a large project might be specified.

  KENNETH FRAMPTON STUDIES IN TECTONIC CULTURE PDF

Commencement of application is acceptance of substrate. A copy of the transport document and manufacturers conformance certificate shall be attached to the material delivery QC form.

Apply approved intetzinc to properly cleaned substrate in accordance with manufacturer’s application instructions.

SECTION HIGH PERFORMANCE SPECIALTY COATINGS

Primer applied off site must be in accordance with the provisions of Section To be selected by Architect from manufacturer’s full range of available colors.

Before proceeding with the work, the applicator will apply the primer and finish coat to a representative substrate section of square feet in size. Protect work area from windblown dust and rain.

Marine, offshore and coastal areas with high salinity. Steel substrate temperature shall be a minimum of 5 deg F 3 deg C above the dew interzimc of the surrounding air for a period of 24 hours prior and during the application of the material.

Upon completion of installation, all excess material, overspray and debris must be cleared and removed from the job site. If necessary for job schedule, the General Contractor shall provide enclosures and heat to maintain proper temperatures and humidity levels in the application areas. Submit manufacturer documentation that the fireproofing product complies with the specified contract requirements.

Do not proceed with remaining intedzinc until workmanship, color, and sheen are approved by Architect. Do not commence application of coatings until the contractor, applicator and inspector have examined the surfaces to receive Work in this section, and determined that the surfaces are acceptable to receive the specified materials.