Fluke — A — Service and User Manual Revision: Manual-ID/Number: Date: 01 2 OPERATING INSTRUCTIONS Fluke Handheld True RMS Multimeter Calibration Manual, PDF, K. Fluke Fluke A Digital Multimeter Instructrion Manual, PDF, M. Digging through my old junk I found an old Fluke A meter. old test leads I need to dig up but does anybody have a manual for this thing?.

Author: Vizshura Fenrinris
Country: Jordan
Language: English (Spanish)
Genre: Environment
Published (Last): 8 September 2015
Pages: 260
PDF File Size: 11.15 Mb
ePub File Size: 11.52 Mb
ISBN: 444-4-61544-237-8
Downloads: 30424
Price: Free* [*Free Regsitration Required]
Uploader: Nikodal

Box 30, Concord, N. Watch list is full. Anti-static bags, for storing S. Please enter a valid ZIP Code.

Four strobe cycles are required to load the new data. Both two- and four-wire measurements can be made on all ranges. For additional information, see the Global Shipping Program terms and conditions – opens in a new window or tab. The shorting links on the front panel make the connection for two-terminal ohms measurements and the input leads attached to the terminals make flule connection during four-terminal ohms measurements.

When the Lockout Strip is properly positioned bend both end tabs up to secure its position. We do not accept any other methods of payment through eBay. Connect the test equipment voltmeter high input lead to TP8 volt supply.

  ARTCUT PLOTTER PDF

Resume making your offer if the page doesn’t update immediately. If any solvent is used, such as freon, it should be kept clear of any switches or potentiomenters since it removes lubrication and shortens their life span dramatically.

Installing the Lockout Strip OA Also the meter didn’t seem to measure properly. Knowing that there is a problem. Co Consumer Products Div. Massachusetts Flhke, Illinois Shakeproof Div. Other offers may also be fluuke. The display should be 1.

Manuals – KO4BB

Please enter up to 7 characters for the postcode. Geneva, New York Ohmite Mfg. Back to home page Return to top. The recommended test equipment for troubleshooting is listed in Table Sell now – Have one to sell? Geneva, Illinois Birnback Radio Co.

It should be Obviously, this technique lends itself to either 8810s or four-terminal measurements. In this configuration it is possible for. Back to home page Return to top.

Maximum calibrator accuracy is attained by using the divider for lower voltage requirements. Each range can be manually selected by depressing an appropriate front panel range switch. City of Industry, California Vernitron Corp. Adjust R3 for a dc voltmeter reading of 0.

  DIETRICH SCHWANITZ BILDUNG PDF

Sign in to check out Check out as guest. When an Ohms Converter Option is installed, the A is capable of making two- or four- terminal resistance measurements.

Stop electronic waste – fix it yourself

Delivery times may vary, especially during peak periods. Refer to eBay Return policy for more details. Garland, Texas Federal Pacific Co. Connect a 1 megohm resistor and flukee 0.

Full text of “FLUKE A”

California Pamotor Div. A calibration interval of 90 days gluke recommended to insure instrument operation within the 90 day specifications.

BZ is presented to U 1 0 as a data input.

Component reference designators mentioned in the text identify the component on the flyke circuit drawings and on the schematic diagrams. Crest factor is 3.

The readout is continuously updated and includes decimal point, polarity Vdc only and a mV dc range annunciator 20 M O and annunciators are also included for use with the Ohms Converter Option.

Seller information mach1metalhead